6.48 mm diameter nozzle delivering 0.91 l/s to the runner which is rotating at 1084 rpm and generating 225 watts into the grid at an overall efficiency of 47%.
Showing posts with label Voltage capping. Show all posts
Showing posts with label Voltage capping. Show all posts

Saturday, 24 October 2020

Repairing and damp-proofing a V-Clamp board

A job, long delayed by uncertainty about how to proceed, has finally been taken off my "to do" list: how to restore Voltage clamp boards which have failed. Time to devote to it happened because of Covid, - a minor bonus in these otherwise difficult times.

Early Powerspout turbines had V-clamp boards to keep voltage within limits when the output from the turbine is to an open circuit; the function of the board is to divert power to a dump load and thereby hold the Powerspout's output to a voltage acceptable to whatever device the turbine is connected to: - either an MPPT controlled battery charger, or as in my case, a grid tied inverter.

When manufactured, the boards were covered with a conformal coating intended to keep the underlying electronics free of moisture, but the coating used was hot melt glue and at low temperatures this becomes brittle, separates from the underlying printed circuit board and develops cracks. Through these cracks, moisture could reach the live circuitry beneath and sooner or later this had terminally disastrous results.  

In the early months of my installation in 2013, two boards died in this way; but the years since have been completely trouble free through EcoInnovation having come up with a one-off special, - special in that the board was entirely encased in an epoxy resin block.

So the long delayed job has been to repair the two boards that died, and then to cast them in epoxy, as had been done for the special.  

Here, in pictures and captions, is the process:

An original board showing how the coating of hot melt glue cracks and separates from the underlying pcb, allowing moisture to enter.
















Typical tell-tale evidence of underlying pcb damage with blackening visible through the conformal coating and molten glue running out. The white stuff is heat conducting paste applied to the heatsinks on the board where they attached to the bulk head of the turbine; the bulk head, being water cooled on the pelton side, creates a good means of dissipating heat from the power electronics on the board.
Initial view of the damage once glue had been removed; since hot melt glue becomes brittle at low temperature, cooling the pcb in the freezer to -18 deg C allowed the coating to be chipped off, but it is a very time consuming process and care is needed not to accidentally remove any surface mounted electronic components. (addendum 9 Feb 2021: see below for an alternative method.)
Later view of damaged area after further cleaning, showing the glass fibre substrate of the pcb has carbonised and copper tracks have been lost; carbon being a conductor, this all had to be removed using a precision rotary tool (Dremel) and the resulting cavity filled with non-conducting epoxy.
Top-side view of the same area of damage; from some components such as the surge protection thermistor in the centre, the hot melt glue could not be removed, so this device was de-soldered and replaced with new; flakes of hot melt glue are still visible around surface mounted components.
Damaged area after repair; the next stage is a final clean with isopropyl alcohol then casting in epoxy
Topside view after repair with a new surge protection thermistor and adjacent capacitor
This is the 'special' made for me by Andrew Smithies, who designed the board; it was with his advice I arrived at my method of casting; one key piece of advice concerned 'thermal runaway'; this is the intense heat generated by two part epoxy compounds as they cure; the heat was so much when he did it that it melted the mould and let some of the epoxy escape; the resulting void had to be filled later with more epoxy; but epoxy added later to already hard-cured epoxy does not unify into one block, so I was keen to avoid this happening.
Before proceeding to casting the repaired pcb I wanted to check it was fully functional; at this stage it was vulnerable to moisture with the bare soldered components having no protection, so testing had to be done on a dry day with low ambient humidity; the test shows volt meters on the two outputs when the turbine was operating without power being fed to the inverter: - the digital voltmeter reads 381v dc, which is the correct voltage for the 400v version of the V-Clamp board, and the AVO analogue meter is reading the voltage being fed to the dump load. The turbine was then allowed to connect to the grid via its inverter and a test was performed to simulate a 'loss of grid' event to check the circuit board instantaneously diverted power to the dump load; all tests were satisfactory and I felt confident the board could be epoxied.
The secret to constructing a mould which can be used more than once is to use material for the mould to which epoxy does NOT bond, and that means polypropylene; a convenient source is a kitchen cutting board and such is what I used, price £7; for the curved bottom, on my first effort, I used a strip of flat rubber sprayed with silicon lubricant to act as a releasing agent; but the epoxy bonded to it and when the mould was disassembled, the rubber had to be carved off the cured epoxy block; on my second effort I used a non-stick sheet, PTFE coated, marketed as oven shelf  liner; it worked fine but needed to be supported by a backing for which lead sheet, as used in roofing, proved OK. Where pp or PTFE is used, no release agent is necessary, - the cured epoxy separates from the mould very easily.
The epoxy I chose to use was "Water clear" Transparent Epoxy Potting Compound from MG Chemicals; I bought it through RadioSpares; for the size of mould I had made each board needed 1.725 litres of epoxy; conveniently for two boards this meant buying one kit of 2.7 litres (RS no: 181-0370) and two kits, each of 375 mls (RS no: 181-0369); each kit comprises resin and hardener in a ratio of 2:1. It is not wise to attempt a mix of 1.725 litres to fill the mould in one go because this will lead to unmanageable thermal runaway; it could get hot enough to damage components on the board; I mixed 300 mls at a time (200 resin + 100 hardener) at half hourly intervals to stagger the curing time and reduce the temperature rise; it therefore took about 2 hrs to fill the mould; even doing it this way, the temperature still reached about 80 deg C and the 300 ml mixes added last cured more quickly than the earlier mixes because the mould had by then begun to get hot.
You are helped to a good outcome in epoxy potting by being well prepared: graduated beakers for mixing resin and hardener, stirring sticks, cleanliness in the work area, a means of de-aerating the mix before pouring it into the mould, a kitchen timer or clock, warming the resin and hardener in the oven to 45 deg C before you start so their viscosity is as low as possible to facilitate mixing and de-aeration. Thorough mixing is particularly important because any resin not mixed with hardener will not cure; it will lead to a sticky patch in the finished block; I stirred for 5 mins timed on a timer; the type of epoxy I was using will remain workable for up to 1 hour at 20 deg C but for less time if it is warmer; each successive mix of 300 mls will bond to the previously poured batch as long as the cure has not reached the stage of being hard, as estimated by whether a finger nail can indent the surface.
Getting the bubbles out after mixing the resin and hardener is important; it can be done by waiting if the mix is not too stiff, or it can be done by placing the mix in a chamber and reducing the pressure; I chose the latter method and used a vacuum cleaner to suck out from a closed container; it seemed to work and I supposed it worked by making the air bubbles in the mix expand and so rise to the surface more quickly.
There are two stages to the curing process, soft cure and hard cure; you don't want to remove the block from its mould until hard cure has reliably been achieved throughout its mass; this can be ensured by 'post-curing' in an oven at 80 deg C for 4 hours, and this is what I did, waiting until the next day when it had cooled down to disassemble the mould.
The result was better than I had expected: the epoxy had filled all crevices and the mould left clean edges; the original V-Clamp board attached to the Powerspout bulkhead with self tapping screws driven in through the bulkhead from the pelton side but a modification in this epoxied board was to incorporate M5 machine screws into the epoxy, onto which Nyloc nuts fasten to draw the heatsinks tight against the bulkhead. I had expected to have to reduce the bulk of the finished block with a disc sander in order to get it to fit in the confined space it occupies above the Powerspout's bearing housing, but in the event it fitted perfectly by entering it from the bottom right side and then rotating it anticlockwise into its final position. 

Conclusion:
The board depicted was installed in the turbine on 7th October 2020 and has so far worked perfectly; it should, I hope, go on working for years to come.
Repairing and epoxying these two boards has not been without expense: the more severely damaged one was beyond my repair abilities and cost £320 to have done professionally. The other board only cost the price of replacing one MOSFET, - a few pence.
Clear epoxy of the type I used is not the cheapest available but I wanted to be able to inspect the encapsulated components should failure occur, - not that repair would be possible once potted.
For each board the epoxy cost worked out at £232.
I did have the option of ditching the present system in which a V-Clamp board is necessary, either by changing to using a Klampit device and continuing with the SMA inverter I use, or by discarding the SMA inverter and changing to one which can accept 600v dc rather than the 400v dc the SMA is designed for.
Either alternative would have meant disrupting a system which has proved bomb-proof for 7 years, and having several spare SMA inverters and V-Clamp boards, I decided to stick with that way of dealing with voltage capping.
Getting to the point of having these two boards repaired and ready for use has been a long journey; for several years I didn't think it was going to be possible; but having done them, and having learned a good deal in the process, I'm glad of having pursued it.

An alternative method to cooling to remove hot melt glue is to use heat; at 120 deg C the glue becomes liquid and drips off; the circuit board is hung in an oven; 


Thursday, 10 September 2015

Capping voltage

In the two years my Powerspout has been operational, the only serious issue occurred soon after commissioning in September 2013.  The problem was a failure of the circuit board housed within the Powerspout casing.  Not one but two boards failed in quick succession. 

At the time, it was pretty disappointing, but I'm happy to give credit where it's due: -  Ecoinnovation were superb in their support both of me and their product, and readily honoured their warranty. They came up with a specially re-worked board encased in epoxy which has stood the test of time and is still the one in the turbine now.

Reading this week of a fellow Powerspout GE400 owner whose board failed in January this year, and for whom Ecoinnovation also readily provided a replacement under warranty despite it being 3 years after his original purchase, I thought the matter worth writing about.  The issue is likely to be something which, sooner or later, will affect anyone with a GE400 turbine.


An original circuit board in situ. The three phase rectifier block on the left acts only to protect the circuit board against possible back flow of power from the inverter.  It is not the main means of ac rectification.

To recap on what this circuit board does and why it is needed: 
  1. it changes the ac output of the SmartDrive alternator to a dc output for the inverter
  2. it ensures the resultant dc output does not exceed 400 volts by two means, the second being failsafe for the first:
    • diverting power to a water cooled heating element when voltage reaches 380 v
    • shorting the output if voltage reaches 400v
  3. capping of the dc voltage output is necessary because an inverter will be irrepairably damaged by voltages greater than its rated input voltage (400 v for the obsolete Sunny Boy 1200 but now 500 or 600 v for current Enasolar inverters)
  4. voltage WILL rise to very high levels when the turbine is unloaded and the electrical output is in open circuit because:
    • the pelton will accelerate to runaway speed (which is ± 1.8 x optimum speed)
    • the voltage output of a pma is speed dependent so as the pelton over-speeds, so over-voltage will result
    • it is a characteristic of pma's that they exhibit poor voltage regulation and voltage rises when there is no circuit connected to the output.
  5. such open circuit / unloaded operation of the turbine / generator is an inevitable occurrence which will happen every time the set is run up (because of the time it takes for the inverter to wake up and check the grid for compatibility before connecting) and every time the inverter disconnects from the grid for whatever reason.

So the need for voltage capping is unavoidable and the V-Clamp board pictured above and devised by Andrew Smithies was a really neat, failsafe and compact solution which tidily sat within the Powerspout casing.  



Unfortunately, that location within the casing was also its Achilles heel.  In spite of the slight warmth created by the alternator, in spite of the ventilation provided by the fins on the rotor, and in spite of giving the board a generous conformal coating of silicone, water penetration to the board led to failures:


Tell-tale ooze of melted silicone with underlying blackening gives away where the problem was on the reverse side of this board





With the silicone removed, there is clear evidence of arcing across the pcb surface between the terminals of this power MOSFET on this board


With circuit board removed leaving behind the white heat transfer paste showing where it was attached, the evidence for water trickling down from the board is clear.  

With several dampness related failures of the board, Ecoinnovation was forced to withdraw from its range the GE400 and other turbines using a similar board.  But with developments in inverter technology which saw inverters able to accept up to 600 v, together with using Smart Drive cores configured to deliver a lower operational voltage and thus lower open circuit voltage, things came together to keep the grid connected Powerspout as a viable option.

The need to cap voltage was not completely eliminated however and instead of the neat arrangement of having the board within the casing, this is now provided by a range of products which need to be housed separately. One of these products comes from a UK company called 2V Microsystems Ltd under their trade name Klampit and another is a product from Chinese company Ginlong.

Sooner rather than later, obtaining a replacement original V-Clamp board is going to be impossible.  When that time comes, moving over to a Klampit will probably be my best option but that will involve, for me, having to figure out where to house the extra components.  Being out in the open, I don't have the wall of a turbine house to mount these extras.

In the mean time, I am hoping that my epoxy encased 'special' will go on working for a while yet.  And in case it doesn't, I have carefully kept my two failed boards as they are repairable if not too badly damaged.  The secret is in knowing how to remove the generous coating of silicone: put the board in the freezer at -23 ℃ for a while and then it mostly breaks away leaving the components on the board pristine.  But be warned, lots of patience and several returns to the freezer will be needed.


My 'special' epoxied board, repair of which will never be possible.  Note also condensation on bulkhead.

Wednesday, 29 October 2014

Low flow matters.

I measured available flow again this morning.  There hasn't been any significant rain, so I wasn't expecting it to be any better, and it wasn't, - only 0.9 lps.

0.9 lps is 30% of the design flow for my scheme (3 lps) and from the graph in my last post, it is clear that a pelton is still pretty efficient at this part flow.  So why can't I be generating with the 0.9 lps available ?  Why is it I'm waiting until flow increases to 1.2 lps ?

The answer lies in what happens to the output voltage of the SmartDrive at low flows.

There are two determinants* of the output voltage of any permanent magnet alternator (pma): rotational speed (rpm) and load. Thus:
  • a decrease in rpm will lower the voltage
  • a decrease in load will raise the voltage

Now the first of these, rotational speed, we can discount as causing voltage change: the rpm at which the pelton and alternator turn are more or less constant and determined by the characteristics of the hydro half of the installation.  Ultimately it is net head which fixes the rotational speed and because net head won't change, rpm won't either. For my set up, it is 1,200 rpm.

So any change in voltage has to result from the second determinant: a change in load, and the only load on the Smart Drive is the inverter.

Recognising that the inverter and pma interact with each other is a key understanding. The inverter, far from being a fixed load of so many ohms, is instead a smart device which can change the load it puts on the system. This is seen in two ways:

1.  a steady 'hunting' of voltage as the MPP tracking function of the inverter continually seeks the optimum voltage and current combination.  This can be seen in the following plot where a SmartDrive with nominal output voltage of 220v dc is seen to hunt up as far as 285 v and down as far as 200 v over the period of time the record was made.

2.  a step change in voltage when nozzles are changed to generate either more or less power according to available flow.  Smaller nozzles generate less power and cause the system voltage to rise. This occurs because the inverter, working in tandem with the pma, presents itself to the pma as a reduced load.  

Thus in my scheme, when power out to the grid is high: 713 W, system voltage is low: 295 ~ 315 v dc (the variability being due to MPP hunting as above), but when ac power out is down: 240 W, system voltage rises to 360 ~ 379 v dc.

The effects of these higher operating voltages are several:
  • higher transmission voltage so less line loss - GOOD
  • higher dc input voltage to inverter reduces its efficiency - BAD
  • dc input voltage rises above inverter MPPT voltage range (100 v ~ 320 v) - BAD
  • Powerspout's V-clamp starts to dump some of the generated power - VERY BAD
So, with the final point, we have at last arrived at the main reason why 1.2 lps is the lowest flow I seem to be able to operate at, - any less and the system voltage rises to be too high, too much of the time: the V clamp spends so much time dumping power that only a small amount (150 W at 0.83 lps) ever gets into the grid through the inverter.

Here is a record of the power output into the grid at two flow levels: 1 lps (237 W) and 0.83 lps (150 W), showing some dumping at the higher level, evidenced by the occasional, random, downward spikes, and at the lower level, the pattern created by more frequent dumping:




Perhaps I should consider buying a different Smart Drive core for use at low flow times of the year: a core wound so that its output voltage stays around 300 v dc when power generated is in the range 100 ~ 260 W.  

They're available from EcoInnovation at $US 199 plus freight.

And that's what I like about this game, - always something new to consider !  Always a new reason to spend !

*There are others, eg magnet field strength, width of air gap between stator coils and rotating magnets, number of poles and whether connected delta or star, but these are not variables in a Smart Drive pma which is installed and functioning.