6.48 mm diameter nozzle delivering 0.91 l/s to the runner which is rotating at 1084 rpm and generating 225 watts into the grid at an overall efficiency of 47%.

Saturday, 10 March 2018

Pictured today...

1. View at the top end
2. View (and sound) at the business end


3. View at the consumption end

Sunday, 4 March 2018

Optimum speed

It's been cold here with temperatures well below freezing. It's a good job that flowing water takes a lot of cold to stop it flowing:


But cold is not what I want to write about in this Diary entry, - rather it is the matter of optimum speed.  
A pelton wheel best converts energy from the force of the jets hitting its cups to rotational energy when it is turning at a particular speed.  That speed will be quite specific to the pelton wheel itself, - size being a major determinant, but also specific to the site at which it is working, - where the net (dynamic) head is a major determinant.

The relationship between rotational speed and power output is commonly presented in text-books in the form of this graph:
 ...which I used in a Diary entry a year ago (see here) to illustrate how changing the speed (by packing off the rotor) had an effect on power output.  As can be gathered from the graph, power as a proportion of maximum power is greatest when speed as a proportion of optimum speed is 1, - i.e. maximum power when speed is at optimum speed.

The difficulty this graph creates for people like me, who want to run their Powerspout so it produces as many kWh's as possible, is the question of what the optimum speed for their particular site is.

To try to answer this question, I have for the past year been measuring speed and efficiency at each and every flow condition at which the turbine has operated.  To date, I have accumulated 29 pairs of speed/efficiency figures, which is enough data to plot a reasonably presentable graph:





Now plotting efficiency against speed is not, of course, the same as plotting [power / optimum power] against speed. Moreover, the efficiency I have used is 'whole system efficiency' rather than 'turbine wheel efficiency', - and 'whole system efficiency' has a lot of variables external to the pelton wheel itself which might corrupt a relationship with speed.

So it is unsurprising that my plot doesn't look exactly like the text-book graph, - it is much 'flatter' in its 'peak'. But I would suggest, nevertheless, that efficiency is a reasonable surrogate for [power/optimum power].  After all, efficiency ought to be highest when speed is at its optimum.

When the graph was first displayed in my computer's spreadsheet, I have to admit to being rather pleased at seeing that its flattish top seems to lie at a shaft speed of around 1050 rpm.

A year ago when I wrote about knowing what my optimum speed might be, I guessed it was between 950 and 1000 rpm.  This latest investigation nudges that guess to a slightly faster speed, - and perhaps gives the new figure an aura of greater respectability by having been arrived at by 'research'.

Having been snowed-in where I live for the past 5 days and with the roads not looking like being clear yet awhile, bringing together this data has, at least, given me something with which to be occupied. Keeping away 'cabin fever' is terribly important !

Saturday, 17 February 2018

Meter deviousness

The 'big six' electricity companies in the UK understandably get concerned when they see from their records that a customer's bills have suddenly become smaller.  If they see that decrease in their income to have coincided with the installation of a 'micro-renewables' at the customer's premises, the conclusion they come to is: the supply meter must be being made to run backwards when energy is exported to the grid.

Such has been the accusation levelled at me in this past week by SSE (Scottish and Southern Electricity).

It is completely reasonable that SSE should want to investigate when they think such a situation has arisen, but the somewhat irritating thing is the way they go about it.  Instead of writing to say what their suspicions are, they say this: "we have come to know that your meter is incompatible with the  micro-renewables system that you have had installed. On a regular basis we extract data from flows that are sent between ourselves and your local network operator. It was highlighted on this report in January that we have come to the knowledge that the meter at your property is incompatible".

Part of the reason why they write such utter nonsense is because the government in the UK has set a target of having 'Smart meters' installed in all domestic premises by the year 2020.  The onus for meeting this target is upon the "big six" electricity companies. So given a situation where they think a meter is running backwards, rather than saying so they just say "your meter needs to be replaced".

From a consumer's point of view however, having an old-style meter replaced by a Smart meter carries implications, - possibly quite major financial implications affecting the income he gets from his "micro-renewables" installation.  This comes about because a Smart meter will measure precisely how much energy is exported, so instead of export payments being based on "deeming", they will come to be based on a metered reading.  For a Powerspout owner where deeming is reckoned at 75% of generated kWh's, this will mean a severe reduction (read here for more about why).  And for people who have any of the devices (such as an Immersun or a SolarCache) that divert surplus energy to alternative loads within the home, - again Smart metering will be a hit on the income they receive from that part of the Feed-in-Tariff which comes from the export payment.

Now SSE is, in my opinion, a good company.  I have held them in high regard ever since they helped with the installation of a 300 kW hydro at a small hospital in Uganda where I used to work (see here).  So when I took up my pen to object to having my meter replaced, and to object to the manifestly fabricated evidence they put forward for replacing it, I did so with a feeling of respect.

The incontrovertible weapon I have for resisting is that my meter does NOT run backwards. So if that argument is their sole reason for insisting on replacement, - their case fails.  If, on the other hand, they were just using that as a Trojan Horse argument in order to get one more old-style meter replaced by a Smart meter to help meet the 2020 target, then they will have to think again.  Although the supply meter at my house is the property of SSE, any change to the installation needs to be made with the agreement of the customer, - and from me that is not likely to be forthcoming.

Post script added 21 Feb 2018: an interesting, if trifling, point of detail came to light after writing the above entry when SSE sent another email explaining why they were so insistent about my meter being able to go backwards. They had the wrong entry in their records for the type of meter I had. They had it recorded as Type C11B2A-R, - which is to say lacking the "H" at the end (see photo below). Apparently the 'H' is all important: lacking it means the meter can go backwards; having it means it can't. So now we know !